Pipe Strain

Static pipe strain and its effects are relatively simple to measure. One method is to disconnect the pipe flanges and measure any piping misalignment. Most companies aim for no more than 0.05mm; difference in distance between the flanges. Furthermore, the bolts should go freely through the holes to align the pipe flanges. To check for the effects of pipe strain on the machine, dial indicators should be mounted vertically and horizontally at each bearing. The dials should be checked as each flange is connected or disconnected. Any movement at the bearing of more than 0.4mm; is generally considered excessive.